dc.contributor.advisor | Bermeo Varón, Leonardo Antonio | - |
dc.contributor.author | García Arias, Lina Vanessa | - |
dc.date.accessioned | 2020-05-16T01:39:41Z | - |
dc.date.available | 2020-05-16T01:39:41Z | - |
dc.date.issued | 2019 | - |
dc.identifier.citation | García Arias, L. V. (2019). Diseño y construcción de un dispositivo de medición de succión en neonatos. Universidad Santiago de Cali. | es |
dc.identifier.uri | https://repository.usc.edu.co/handle/20.500.12421/2957 | - |
dc.description | El reflejo de succión es innato y debe funcionar adecuadamente en términos de su capacidad y coordinación con los demás reflejos involucrados en el proceso de alimentación, evitando complicaciones metabólicas, lingüísticas y neuronales, que al no ser atendidas oportunamente pueden llevar incluso a la muerte del recién nacido. En América latina los métodos más comúnmente empleados son cualitativos e inexactos, basados en escalas de evaluación subjetivas como la escala NOMAS (Neonatal Evaluation Scale of the Oral Motor) y la establecida por Virginia Apgar en 1953. En el presente estudio, se desarrolló un novedoso sistema inalámbrico para la medición cuantitativa y objetiva del reflejo de succión en recién nacidos que permite extraer parámetros a partir de los diferentes patrones de succión en tiempo real. El sistema de medición propuesto consiste en un dispositivo de detección de fuerza de succión, compuesto por una tetina artificial que incluye un sensor de fuerza resistiva incorporado (RFP-602e). Los datos de succión se envían mediante Bluetooth a una computadora portátil, en la cual se desarrolló un programa en el entorno de programación MATLAB® para recibir, mostrar y almacenar los patrones de succión. Las pruebas experimentales incluyen diez recién nacidos a término del Hospital Siloé Siglo XXI, que está adscrito a la Red de Salud Ladera, en Santiago de Cali, Colombia. Los resultados muestran que el sistema propuesto es adecuado para medir el comportamiento de succión de los bebés, incluso dentro de unas pocas horas de vida, lo que podría ayudar a los médicos a detectar oportunamente el riesgo del retraso del desarrollo infantil en el futuro. | es |
dc.description.abstract | The sucking reflex is innate and must function properly in terms of its capacity and coordination with the other reflexes involved in the feeding process, avoiding metabolic, linguistic and neuronal complications, which if not attended to in time can lead to death of the newborn . In Latin America, the most methods used are qualitative and inaccurate, based on subjective evaluation scales such as the escalation of NOMAS (Scale of Neonatal Evaluation of the Oral Engine) and the one established by Virginia Apgar in 1953. In the present study, we describe a new wireless system for the quantitative and objective measurement of the sucking reflex in newborns that allows obtaining the results of different sucking patterns in real time. The measuring system consists of a resistive force sensor (RFP-602e). The sucking data is sent via Bluetooth to a portable computer, in which a program was developed in the MATLAB® programming environment to receive, display and store the sucking patterns. A total of ten term newborns were recruited from The Siloé siglo XXI Hospital, which is attached to the Ladera Health Network, in Santiago de Cali, Colombia. Results show that the proposed system is adequate to measure the sucking behavior of babies, even within a few hours of life, which could help doctors to detect in a timely manner the risk of delayed child development in the future. | es |
dc.format | application/pdf | - |
dc.format.extent | 39 páginas | - |
dc.language.iso | es | es |
dc.publisher | Universidad Santiago de Cali | es |
dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | - |
dc.subject | Reflejo de Succión | es |
dc.subject | Neonatos | es |
dc.subject | Evaluación Cuantitativa | es |
dc.subject | Sensor Resistivo de Fuerza | es |
dc.title | Diseño y construcción de un dispositivo de medición de succión en neonatos | es |
dc.type | Thesis | es |
dc.publisher.faculty | Facultad de Ingeniería | - |
dc.pubplace.city | Cali | - |
dc.rights.acceso | Acceso Abierto | - |
dc.rights.cc | Reconocimiento 4.0 Internacional (CC BY 4.0) | - |
dc.source.repository | Repositorio Institucional USC | - |
dc.source.institution | Universidad Santiago de Cali | - |
dc.type.spa | Trabajo de Grado | - |
dc.creator.degree | Trabajo de grado para optar al título de Bioingeniería | - |
dc.publisher.program | Bioingeniería | - |
dc.pubplace.state | Valle del Cauca | - |
dc.subject.keyword | Sucking Reflex | - |
dc.subject.keyword | Newborns | - |
dc.subject.keyword | Quantitative Assessment | - |
dc.subject.keyword | Resistive Force Sensor | - |