dc.identifier.citationMéndez Arana, M. I. (2019). Evaluación del efecto de la reutilización sobre dispositivos médicos de único uso en una institución de salud del Valle del Cauca. Universidad Santiago de Cali.es
dc.identifier.urihttps://repository.usc.edu.co/handle/20.500.12421/4256-
dc.descriptionLa reutilización de dispositivos médicos de único uso (DMUS) es una práctica común en las instituciones de salud de nuestro país. A pesar de que esto pueda generar consecuencias para los pacientes, su amplia utilización se debe a los costos de adquisición de dispositivos nuevos, a la reducción de residuos médicos y al impacto positivo en la accesibilidad a los servicios de salud. En Colombia no existe alguna normativa clara que prohíba la reutilización de DMUS; por el contrario, la resolución 2003 de 2014 permite la reutilización de un dispositivo médico de único uso, siempre y cuando se tenga evidencia científica sobre su seguridad. Para este estudio se realizó un análisis y caracterización de cinco tipos DMUS reutilizados en una institución de salud del Valle del Cauca: máscara inflable de anestesia, la pieza de mano vitrectomía 23G, el cassette combinado constellation y las fresas índigo pulidoras y cortantes, para lo cual se identificaron los procedimientos de reutilización y se aplicaron pruebas de laboratorio de análisis microbiológico, análisis estructural y pruebas de fugas, para verificar las características funcionales de cada tipo de dispositivo médico. Como resultado de este estudio se evidenció que las máscaras inflables para anestesia pueden ser reutilizado un máximo de cinco veces, la pieza de mano vitrectomía 23G podría ser reutilizada dos y hasta tres ciclos más, el cassette constellation puede ser reutilizado hasta un quinto ciclo con la posibilidad de reutilización en un ciclo adicional, las fresas con incrustación de diamante pulidoras con un máximo de dos veces y para los dispositivos médicos fresas cortantes se propone un estudio posterior donde sea realizado un análisis metalográfico y de dureza especializado por evidencia de deformaciones halladas durante los análisis estructurales.es
dc.description.abstractThe reuse of single-use medical devices (SUDs) is a common practice in our country's health institutions. Although this may lead to consequences, their extensive use is due to the costs of acquiring new devices, hazardous medical waste reduction and the positive impact on accessibility to health services. In Colombia there is no regulation that prohibits the reuse of SUDs; otherwise, the Colombian norm “resolution 2003 of 2014”, allows the reuse of a single-use medical device, as long as there is scientific evidence about its security. For this study, an analysis and characterization of five reused SUDs types in a Valle del Cauca health institution was performed: the inflatable anesthesia mask, the 23G vitrectomia handpiece, the combined constellation cassette and indigo cutters polishing and shearing, for which reuse procedures were identified and laboratory tests were applied for microbiological analysis, structural analysis and leak testing, to verify the functional characteristics of each type of medical device. As a result, it was shown that inflatable masks for anesthesia can be reused a maximum of five times, the handpiece vitrectomia 23G could be reused two and up to three more cycles, the constellation cassette can be reused up to one fifth cycle with the possibility of reuse in an additional cycle, diamond-encrusted milling cutters with a maximum of twice and for medical devices cutting cutters is left in a subsequent study where a metallographic and specialized hardness analysis will be performed by evidence of deformations found during structural analyses.es
dc.formatapplication/pdf-
dc.format.extent48 páginas-
dc.language.isoeses
dc.publisherUniversidad Santiago de Calies
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/-
dc.subjectReutilizaciónes
dc.subjectDispositivos Médicoses
dc.subjectCaracterizaciónes
dc.subjectResiduoses
dc.titleEvaluación del efecto de la reutilización sobre dispositivos médicos de único uso en una institución de salud del Valle del Caucaes
dc.typeThesises
dc.publisher.facultyFacultad de Ingeniería-
dc.pubplace.cityCali-
dc.rights.accesoAcceso Privado-
dc.rights.ccReconocimiento 4.0 Internacional (CC BY 4.0)-
dc.source.repositoryRepositorio Institucional USC-
dc.source.institutionUniversidad Santiago de Cali-
dc.type.spaArtículo-
dc.creator.degreeTrabajo de grado para optar al título de Bioingeniería-
dc.publisher.programBioingeniería-
dc.pubplace.stateValle del Cauca-
dc.subject.keywordReuse-
dc.subject.keywordMedical Devices-
dc.subject.keywordCharacterization-
dc.subject.keywordHazardous Medical Wastes-
Appears in Collections:Bioingeniería

Files in This Item:
File Description SizeFormat 


This item is licensed under a Creative Commons License Creative Commons